Go back to home

Valve clearances for 1V 1600 xflow

Author
ratta tat tat
Supporter
  • Total Posts : 1633
  • Scores: 39
  • Reward points: 5492
  • Joined: 2011/08/01 11:02:49
  • Location: Brisbane
  • Status: offline
2010/12/30 03:28:46 (permalink)
0

Valve clearances for 1V 1600 xflow

I've adjusted my valves to the specs from a 1975 haynes manual, (pre ADR27a) which is a high compression 2V engine. The specs were:
inlet 0.25mm exhaust 0.55mm.

Can someone please give me the specs for my 1976 1V engine? Many thanks in advance
#1


4 Replies Related Threads

    Neale
    Enthusiast
    • Total Posts : 109
    • Scores: -1
    • Reward points: 1314
    • Joined: 2011/08/01 11:02:49
    • Location: Bathurst NSW
    • Status: offline
    RE: Valve clearances for 1V 1600 xflow 2010/12/30 11:04:07 (permalink)
    0
    Not Sure as it doesnt specify if it is 1V or 2V but Ive just checked a 1977 Mk2 Escort Ford Workshop Manual for the L, GL and GHIA & it states that the the 1600 OHV motor that is used.

    So if this is any help the Valve Clearances for this motor are
    Inlet - 0.20 mm (0.008 in.)
    Exhaust - 0.55 mm (0.022 in.)
    #2
    gtv6capri
    Deity
    • Total Posts : 1461
    • Scores: 53
    • Reward points: 5548
    • Joined: 2011/08/01 11:02:49
    • Location: Melbourne Vic Australia
    • Status: offline
    RE: Valve clearances for 1V 1600 xflow 2010/12/30 11:49:46 (permalink)
    0
    8 and 18 according to my memory for the 1600hc (non 2v) pre pollution
    #3

    ratta tat tat
    Supporter
    • Total Posts : 1633
    • Scores: 39
    • Reward points: 5492
    • Joined: 2011/08/01 11:02:49
    • Location: Brisbane
    • Status: offline
    RE: Valve clearances for 1V 1600 xflow 2010/12/30 14:36:52 (permalink)
    0
    quote:
    Originally posted by Neale

    Not Sure as it doesnt specify if it is 1V or 2V but Ive just checked a 1977 Mk2 Escort Ford Workshop Manual for the L, GL and GHIA & it states that the the 1600 OHV motor that is used.

    So if this is any help the Valve Clearances for this motor are
    Inlet - 0.20 mm (0.008 in.)
    Exhaust - 0.55 mm (0.022 in.)



    Perfect, thanks Neale
    #4
    ratta tat tat
    Supporter
    • Total Posts : 1633
    • Scores: 39
    • Reward points: 5492
    • Joined: 2011/08/01 11:02:49
    • Location: Brisbane
    • Status: offline
    RE: Valve clearances for 1V 1600 xflow 2010/12/30 14:46:49 (permalink)
    0
    quote:
    Originally posted by gtv6capri

    8 and 18 according to my memory for the 1600hc (non 2v) pre pollution




    [x2x] My Haynes manual is for the 1.1, 1.3 and 1.6 1975 escort. It only makes reference to a 2V 1600, not HC.
    #5
    Jump to:
    © 2025 APG vNext Trial Version 5.1